Preventing Fixture Overturning

  • To preclude overturning, the height of the upright cannot exceed the leveler spacing dimensions multiplied by six
  • If uprights exceed the heights shown, they must be secured at the top, or one of the following corrections must be made: ° Gondola: Base Shoe Levelers must be anchored to the floor as shown below ° Wall: Base Shoe Levelers and Standard Upright Levelers must be anchored to the floor as shown below
anchors, heavy-duty, seismic, sfa